Details, datasheet, quote on part number: CKRA2410R
PartCKRA2410R
CategoryDiscrete => Solid State relays
DescriptionZero Cross0.15-10 Amps RMS24-280 Volts RMS90-280 Control - Volts RMS
CompanyCrydom Corporation
DatasheetDownload CKRA2410R datasheet
Cross ref.Similar parts: RN1B23A10U
Quote
Find where to buy
 
  

 

Features, Applications

SCR Output utilize Crydom's proprietary thermal management technology providing & 30A Models compact and efficient design. Built-in Ground Terminal Included DIN Rail attachment, easy-to-use Box Zero Voltage and Random Clamp type terminals and integral heat sinking complete the package. This Turn-On Switching compact new design offers to 30Arms Low Leakage in ambient temperatures of 25C. Integral Heatsink (22.5 mm) Manufactured in Crydom's ISO 9001 DIN Rail & Panel Mount Certified facility for optimum product Status Indicating LED performance and reliability. or AC Control Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P Option)

Operating Voltage (47-63 Hz) [Vrms] Max. Load Current @ 25C Ambient Temperature [Arms] Min. Load Current, [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Maximum 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/sec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load

1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) 0.5 DC CONTROL 4.5-32 Vdc 4.5 Vdc 1.0 Vdc 0.5 AC CONTROL Standard 90-280 Vrms 90 Vrms 10 Vrms 0.5 AC CONTROL (E Suffix) 18-36 Vrms 18 Vrms 4.0 Vrms

Control Voltage Range Max. Turn-On Voltage Min. Turn-Off Voltage Typical Input Current
2001 CRYDOM CORP, Specifications subject to change without notice.

GENERAL NOTES All parameters at 25C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Turn-on time for DC control random turn-on versions is 0.02msec. Input circuitry for DC control version incorporates active current limiter.

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: (0)1202 365070 FAX (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY:

GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Status Indicating Display MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Terminals: Maximum Wire Size: Max. Terminal Screw Torque Min. Side by Side Spacing CURRENT DERATING CURVES

Thermally Conductive Epoxy Box Clamp Type AWG (0.6Nm) 0.8 inch (20mm)

AVAILABLE OPTIONS P 24 Vac Input (18-36 Vac) Example: CKRA2410E Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Example: CKRD2410P (AC & DC Control) Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: CKRD2410R

For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: (0)1202 365070 FAX (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY:


 

Related products with the same datasheet
CKRA2410E
CKRA2410ER
CKRA2420
CKRA2420E
CKRA2420ER
CKRA2420R
CKRA2430
CKRA2430E
CKRA2430ER
CKRA2430R
CKRD2410
Some Part number from the same manufacture Crydom Corporation
CKRA2420 Zero Cross0.15-10 Amps RMS24-280 Volts RMS90-280 Control - Volts RMS
CKRA4810 Zero Cross0.15-10 Amps RMS48-530 Volts RMS90-280 Control - Volts RMS
CKRD2410 Zero Cross0.15-10 Amps RMS24-280 Volts RMS90-280 Control - Volts RMS
CKRD4810 Zero Cross0.15-10 Amps RMS48-530 Volts RMS90-280 Control - Volts RMS
CMA24110 Zero Cross0.25-110 Amps RMS24-280 Volts RMS90-140 Control - Volts RMS

B482F-2 : Power Module

B613SE-2T : Power Module

EFG16EF : Power Module

PRGD48150-10 : Zero Cross0.15-150 Amps RMS24-280 Volts RMS90-140 Control - Volts RMS

CTA06-600TW : Triacs 6A Triacs 6A 400V - 1000V Isolated and non-isolated Types: Logic level, alternistor (No snubber) and standard (Four quandrant triggering) TO-220AB package

CWD24125H-10 : Panel Mount

H12WD4890PH : Panel Mount

MCTC2490JEHD : 25-90Amp - 120/480 Vac - AC OUTPUT The Crydom MCTC is a unique self-contained state of the art basic Temperature Controller that combines all the necessary fuctions into one easy to set up and use standard size package. The MCTC is ideal for temperature control users that do not need multiple

DRA3P48A4 : Solid State Relay Module 3PST (3 Form A); RELAY CONT 3PH 480VAC 4A 220VAC Specifications: Mounting Type: DIN Rail ; Termination Style: Screw Terminal ; Package / Case: Module ; Circuit: 3PST (3 Form A) ; Load Current: 4.2A ; Voltage - Input: 200 ~ 265VAC ; Voltage - Load: 48 ~ 510 V ; Output Type: AC, Zero Cross ; On-State Resistance: - ; Lead Free Status: Lead Free ; RoH

MCSS2450BS : Solid State Relay Hockey Puck SPST-NO (1 Form A); RELAY START/STOP 240V 50A AC OUT Specifications: Mounting Type: Chassis Mount or Panel Mount ; Termination Style: Screw Terminal ; Package / Case: Hockey Puck ; Circuit: SPST-NO (1 Form A) ; Load Current: 50A ; Voltage - Input: 8 ~ 32VDC ; Voltage - Load: 180 ~ 280 V ; Output Type: AC, Linear Controlled ; On-State Resistance: - ; L

CSD2425F-10 : TRIGGER OUTPUT SOLID STATE RELAY, 4000 V ISOLATION-MAX Specifications: Mounting: PLASTIC PACKAGE-4 ; Maximum Switching Current: 25.00 amps ; Isolation Voltage: 4 kilovolts ; Operating Temp: -40 to 176 F (233 to 353 K)

 
0-C     D-L     M-R     S-Z